WFX-130B Atomic Absorption Spectrophotometer

WFX-130B Atomic Absorption Spectrophotometer
Product Detailed
Model WFX-130B Atomic Absorption Spectrophotometer, flame type, Fully automatic PC control, 4-lamp, D2 background correction

Atomic Absorption Spectrophotometer

Model: WFX-130B

FEATURES:

1  Accurate fully automated control system

1.1  Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position

1.2  Automatic wavelength scanning and peak picking

1.3  Automatic spectral bandwidth changing

1.4  Automatic ignition

2  Perfect safety protection measures

Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

3  Advance and reliable electronic design

3.1  Adopting large-scale programmable logic array and Inter 12C bus technology

3.2  European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

4  Easy and practical analysis software

4.1  Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization

4.2  Automatic display of measured data, automatic caculatiion and analytical result automatic print out.

Main Specification

Wavelength range

190-900nm

Wavelength accuracy

±0.25nm

Resolution

Two spectral lines of Mn at 279.5nm and

279.8nm can be separated with the spectral

bandwidth of 0.2nm and valley-peak energy

ratio less than 30%.

Baseline stability

≤0.004A/30min

Background correction

The D2 lamp background correction

capability at 1A is better than 30 times.

Light Source

Lamp turret

4-lamp turret

auto alignment, fully automated scan and

peak-picking.

Lamp current adjustment

Automatic adjustment and display.

Wide pulse current: 0~25mA,

Narrow pulse current: 0~10mA                

Lamp power supply mode

400Hz square wave pulse

 

Optical System

Monochomator

Single beam, Czerny-Turner design grating

monochromator

Grating

1800 l/mm

Focal length

277mm

Blazed Wavelength

250nm

Spectral Bandwidth

0.1nm, 0.2nm, 0.4nm, 1.2nm automatic

change.

Flame Atomizer

Burner

10cm single slot all-titanium burner  

Spray chamber

Corrosion resistant all-plastic spray chamber.

Nebulizer

High efficiency glass nebulizer with metal

sleeve, sucking up rate: 6-7mL/min

Detection and Data Processing System

Detector

R928 Photomultiplier with high sensitivity and

wide spectral range.

Software

Windowsoperating system

Analytical method

Working curve auto-fitting; standard addition

method; automatic sensitivity correction; automatic calculation of concentration and content.

Repeat times

Maximum 20 times of repeat measurement,

automatic calculation of mean value,

standard deviation and relative standard

deviation.

Multi-task function

Sequential measurement of multi-elements in

one sample

Condition reading

With model function

Result printing

Measurement data and final analytical report

printout, editing with Excel.

Standard RS-232 serial port communication

Characteristic Concentration and

Detection Limit

Normal Air-C2H2 flame

Cu: Characteristic concentration≤0.025mg/L,

Detection limit≤0.006mg/L;

Function Expansion

Hydride vapor generator can be connected for hydride analysis.

Dimensions and weight

1020 (L) × 490(W) × 540 (H) mm (main unit), unpacked 80kg