WFX-310 Atomic Absorption Spectrophotometer

WFX-310 Atomic Absorption Spectrophotometer
Product Detailed
Model WFX-310 Atomic Absorption Spectrophotometer, flame type, Microprocessor control, LED display, D2 background correction

Atomic Absorption Spectrophotometer

Model: WFX-310

FEATURES:

1  High cost-effctive flame AAS

Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less automation to provide an economic model for users

2  Reliable integration of main unit with microprocessor

Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument

3  Simple and easy operation

Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy and fast analysis

SPCIFICATIONS:

Main Specification

Wavelength range190-900nm
Wavelength accuracy±0.5nm
ResolutionTwo spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability0.005A/30min
Background correctionThe D2 lamp background correction capability at 1A is better than 30 time
Light Source SystemLamp turret2 lamps are powerd simultaneously (one preheated)
Lamp current adjustment

0~20mA

Lamp power supply mode

400Hz square wave pulse;

Optical SystemMonochomatorSingle beam, Czerny-Turner design grating monochromator
Grating1800 l/mm
Focal length277mm
Blazed Wavelength250nm
Spectral Bandwidth0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change
AdjustmentManual adjustment for wavelength and slit
Flame AtomizerBurner10cm single slot all-titanium burner
Spray chamberCorrosion resistant all-plastic spray chamber
NebulizerHigh efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Position adjustmentManual adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner/min
Gas line protectionFuel gas leakage alarm/min
Detection and Data Processing SystemDetectorR928 Photomultiplier with high sensitivity and wide spectral range.
Electronic and micro-computer systemAutomatic adjustment of light source power. Light energy and negative high-voltage auto-balance
Display modeLEC display of energy and measurement values, concentration direct reading.
Read modeTransient, time average, peak height, peak area, integral time is selectable in the range of 0.1~19.9s.
Scale expansion0.1~99
Data processing modeAutomatic calculation of mean, standard deviation and relative standard deviation. Reporting number is in the range of 1~99
Measurement modeAutomatic cureve fitting with 3~7 standards; Sensitivity auto-correction
Result printingMeasurement data, working curve, signal profile and analytical conditions can all be printed out
Instrument self-checkCheck current status of each function key
Characteristic Concentration and Detection LimitAir-AcetyleneCu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Function ExpansionHydride vapor generator can be connected for hydride analysis
Dimensions and weightMain unit102×49×54cm, unpacked 80kg